To reset the pump to the factory default settings:
- Ensure that the pump is powered on and the green power LED is on.
- Press the Stop button to stop the pump.
- Press and hold all of the four Speed buttons simultaneously for four seconds. Power off the drive.
Subsequently, how do I reset my Pentair Intelliflo pump after a power outage?
How to “restart” your pool once power is restored
- Remove the pool cover and check for debris. …
- Close any drain plugs or valves you may have opened during the power outage.
- Turn the breakers back on and prime the pool pump by adding water to the pot, replace the lid and turn the pool pump on.
Just so, how do I reset my Pentair variable speed pump?
Why does my Pentair pump keep stopping?
There are several reasons why your pump may randomly shut off—a behavior known as “pump tripping.” Most commonly, your pump may be operating at the wrong voltage, overheating, or simply failing to compete with your neighborhood’s electrical needs.
Where are Pentair pool pumps manufactured?
Our manufacturing plant, located in St. Paul, Minneapolis, USA, produces products for fluid processing, respiratory, membrane, blood line and systems.
How do I program my Pentair Intelliflo pool pump?
How do I reset my Pentair antenna?
You can use a paper clip to reset the Protocol Adapter by pressing the recessed reset button. You canunplug and plug back in the wireless router to reset it.
Why won’t my pool pump come on?
When a pump doesn’t turn on or starts shutting off quickly after it’s started, it’s usually an electrical problem, which could mean loose connections, a bad capacitor or overloaded voltage. But it could also be a jammed motor.
How do I restart my pool pump?
Steps to Prime Your Pool Pump
- Turn off the pump. …
- Switch to recirculate. …
- Release air. …
- Clean out the pump basket. …
- Fill the pump basket. …
- Once the pump basket is filled and tightened, make sure the air release valve is open and turn the power to the pump on.
- Check the water flow to your pump.
How do I replace the shaft seal on my pool pump?
What does overcurrent mean on a pool pump?
Over Current
Indicated that the drive is overloaded or the motor has an electrical problem. The drive will restart 20 seconds after the over current condition clears.
What RPM should I run my Pentair pool pump?
Suction cleaners typically run at around 2200-2400 RPM. Heaters require 20 to 40 Gallons Per Minute (GPM) so might run at around half speed or a little higher. You would probably want to run your Spa at up to full speed, 3450, for maximum effect.
Why is my pool pump not working?
It could be something blocking it, a dirty pool filter, or too much air in the system. If there’s something blocking your pump’s suction, check your filter gauge. If it’s 10psi above the normal reading, clean your filter. This will reduce pressure and reset your pump’s flow.
Why does my pump keep turning off?
A blockage in the water supply piping.
For example, a clogged or nearly clogged water filter can cause the pump control to cycle on and off rapidly. This is because the blockage causes water pressure (between the pump and the filter) to rise very rapidly when the pump turns on.
How do you reset the schedule on a Pentair de pool pump?
How do I set the schedule on my Pentair IntelliFlo?
How many hours should I run my variable speed pool pump?
However, it is important to note that a variable speed pool pump should ideally be running 24 hours a day to ensure proper and optimal water circulation. When your pool pump is not running, the water is sitting stagnant in your pool allowing bacteria to survive and grow.
How do I reset my Pentair pool timer?
How to Set the Date/Time on the Pentair Intelliflo
- From the home screen, press the “Menu” button.
- Use the Up or Down Arrows to cycle to “Settings”
- Press “Select”
- Cycle to “Date/Time”
- Press Select.
- You will see the factory default Date, press “Select” again to edit.
Why is my pool pump leaking from the bottom?
In most cases, a leak underneath a pool pump is caused by a pressure-side leak. This is easily combated by inspecting the impeller housing o-ring, shaft seal and replacing any worn, cracked o-rings or seals. Before taking apart your pool pump, we recommend purchasing a go-kit.
How do I adjust my Pentair pool pump?
How do I reset my Pentair easy touch?
Why does my Pentair pump shut off?
Overheating. For safety reasons, many pool pumps are designed to shut off automatically if they begin to overheat. The mechanisms that perform this task are known as thermal overload switches. If your pump continues to shut off, it could mean that the thermal overload switches are going bad.
Why does my IntelliFlo pump keep shutting off?
It could be a bad drive, over voltage, under voltage, drive over heating, ect. You could eliminate it being a control problem by unplugging the control cable on the motor, and manually running it. If it does not do it anymore then it is a control issue.
How do I reset my ScreenLogic protocol adapter?
unplug and plug back in the wireless router to reset it. 3. Verify the wiring to the protocol adapter and IntelliTouch Load Center.
How do you unlock Pentair Intelliflo?
Make sure the pump has power, green LED is on. Make sure the pump is not running. Press and hold all of the four Speed buttons simultaneously for four (or more) seconds. Power off the pump, wait a few seconds, power it back on.
Why is my water pump not working after power outage?
Often when there is no water after a power outage it is due to the low-pressure switch. This is because the tank has to have a certain amount of pressure to keep the water levels where they need to be. When there is no power, the pressure drops and causes the pressure to drop. This then causes the water levels to drop.
How do you reset the pool timer after a power outage?
How does Pentair freeze protection work?
The system detects all devices that have Freeze Protection ON, and activates the device to stop the pipes from freezing. If freeze protec- tion is only applied to one body of water. Note: If the pool or spa is running a schedule or operated manually, this will override freeze protection.
How do I start my Pentair pool pump?
Why will my pool pump not turn on?
When a pump doesn’t turn on or starts shutting off quickly after it’s started, it’s usually an electrical problem, which could mean loose connections, a bad capacitor or overloaded voltage. But it could also be a jammed motor. All of these things are usually fairly simple fixes.
How do I reset my Pentair pool pump?
How do you troubleshoot a Pentair pool pump?
How do you program a Pentair Intelliflo variable speed pump?
How do I fix my pool pump?
How do I know if my pool pump motor is bad?
Don’t Wait to Call for Swimming Pool Pump Replacement
- Age. Yes, the age of your pump is an early trouble sign. …
- Noise. Your pool pump should run quietly. …
- Power Trip. Has your pool pump motor started to trip your electric breaker box more and more frequently? …
- Swimming Pool Pump Motor Keeps Shutting Off. …
- Loss of Suction.
How long does it take for pool pipes to freeze?
If you have an above ground pool with the pool filter system and plumbing above ground (like nearly all above ground pools), pipes and pumps can freeze up in less than an hour of minus 32 degrees.
How do I program my Pentair Intelliflo VSF?
How do you fix a Pentair pump?
How do I change the shaft seal on my pool pump?
Remove the old seal half from the back of the impeller. Clean up the seal plate, impeller and motor shaft surfaces if they are dirty or rusty. Push the new donut half firmly into the seal plate, using the cardboard piece, to keep it clean.
How do you fix a noisy pool pump motor?
Feel the impeller to see if it’s clogged or wobbly—both will cause a noisy pump. If it’s clogged, bend a stiff piece of wire into a hook shape with a pair of pliers, and use that to scrape off the debris. If the impeller is wobbly, you’ll need to have it adjusted or replaced.
Why does my pool timer not work?
If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears (I once found a gecko tail), or the timer motor has burned out. It could also be loose wires, either on the time clock terminal board, or on the timer motor.
How do you manually turn on a pool pump?
Why does my pool keep turning on and off?
If you have a new pump or pool, your pump might be wired incorrectly or loosely! In the case your pump turns off a few seconds after turning it on you might even have a bad capacitor. Capacitors regulate the amount of power the pump gets and can go bad with age.
Why does my pool pump keep tripping off?
The most common reasons for a pool pump circuit breaker to trip are an overloaded motor, underrated pump breaker, bad motor windings or other earthing issue, moisture in the motor or moisture in the wiring.
How do I turn on my Pentair pool pump?
How do you reset the time on a Pentair pool pump?
How do I manually start my Pentair pool pump?
Why does my pool pump turn on randomly?
Does your pump turn on at night by itself? It is doing so because the computer control has a freeze sensor. when the temperature drops below 36 degrees Fahrenheit, the system will turn on the pump. This is to prevent water from freezing in the pipes.
How much does it cost to replace bearings in a pool pump?
With the cost of parts at roughly $30 (including the shaft seal), a bearing job can be an inexpensive fix. A caveat: It’s not uncommon for a bearing replacement to last less than a year. Also, the more times a bearing is replaced, the less likely it would seat in the end bell properly.
How do you reset pool pump after power outage?
How to “restart” your pool once power is restored
- Remove the pool cover and check for debris. …
- Close any drain plugs or valves you may have opened during the power outage.
- Turn the breakers back on and prime the pool pump by adding water to the pot, replace the lid and turn the pool pump on.
How do I program my Intelliflo 2 VST?
What is thermal mode on pool pump?
This feature allows you to set a speed (450- 3450 RPM) or flow (20-140 GPM) that runs when the IntelliFlo® VSF Variable Speed and Flow Pump goes into Thermal Mode. The temperature level that you wish Thermal Mode to start can also be set. IMPORTANT: This feature is for protection of the pump.
How do you prime a Pentair Intelliflo pump?
How To Prime Your Pentair Pool Pump
- Turn off power to pump (switch and breaker)
- Using black 3 way valve, turn off Skimmer (main drain on only)
- Remove pump lid.
- Fill pump with water all the way to top.
- Put pump lid back on.
- Turn on Pump.
How long should I run my Pentair Intelliflo pump?
How do I program a Pentair IntelliFlo 2 VST?
How do I turn on my pool pump Pentair Easytouch?
How do you turn off Pentair egg timer?
If you desire a different method of operation, programs 3 and 4 can be changed to Manual mode in the control menu. To operate in Egg Timer mode, press a program button and then press Start/Stop. The pump will run that setting for the set amount of time and then turn off.
What RPM should I set my pool pump to?
For example, for the first few days, you might run the pump at 2500 RPMs to see what your pool looks like. Next, you might dial it down to 1600 RPMs. If after a few days your pool starts to look cloudy or hazy, you can set the pump to run at 2000 RPMs.
How do you change a Pentair pump seal?
How do you program a variable speed pool pump?
Is there a reset button on a Pentair pool pump?
TO PERFORM A FACTORY RESET:
Press Start/Stop to stop the pump. 2. Record all of the custom schedule settings and the priming speed in Table 3. These settings can be found by pressing the “1”, “2”, “3”, and “Quick Clean” buttons and cycling through all the screens.
How do I fix error code 0021?
The manual states: “– Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the back side of the keypad inside the drive top cover. Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable.”
Why does my Pentair pump keep shutting off?
Overheating. For safety reasons, many pool pumps are designed to shut off automatically if they begin to overheat. The mechanisms that perform this task are known as thermal overload switches. If your pump continues to shut off, it could mean that the thermal overload switches are going bad.
How do I reset my Intelliflo VSF?
Is there a reset button on Pentair pool pump?
Why is my pool pump motor making a loud noise?
The most common reasons for a noisy pool pump include blocked lines, a blocked impeller, faulty bearings and seals or unsecure mountings. The problems cause noises including loud rattling, grinding, gurgling, whining, buzzing, high pitched noises and vibrations. Many pump noises can be fixed in just a few steps.
How do you manually start a Pentair pool pump?
Is it worth repairing a pool pump?
So generally, if you run across problems with your pool pump before the five or six year mark or if it’s still covered by warranty, then repairing it is the way to go, after that mark, you may have to think about getting a new pool pump altogether as the other components of the pump may start to fail anytime as well.
How do you reset Pentair?
TO PERFORM A FACTORY RESET:
Press Start/Stop to stop the pump. 2. Record all of the custom schedule settings and the priming speed in Table 3. These settings can be found by pressing the “1”, “2”, “3”, and “Quick Clean” buttons and cycling through all the screens.
Why does my pool pump keep turning on and off?
If you have a new pump or pool, your pump might be wired incorrectly or loosely! In the case your pump turns off a few seconds after turning it on you might even have a bad capacitor. Capacitors regulate the amount of power the pump gets and can go bad with age.